Data Sciences International
  • Home

DSI PhysioTel® PA-C40 for Small Animals

The PhysioTel® PA series transmitter model PA-C40 measures pressure and activity in small animals. Other models in the PhysioTel® PA series transmitter series include PA-C10 for mice and PA-D70 for large animals.

This model is capable of measuring arterial, ocular, uterine, penile, bladder, pleural and left ventricular pressure. Other parameters such as heart rate, systolic, diastolic and mean pressure can be derived from these waveforms. Similar to all models in the PA transmitter series, the PA-C40 is completely implantable, eliminating the need for flushing and other catheter maintenance issues.

PA-C40 Specifications

Weight (gm)

7.6

Volume (cc)

4.4

Minimum Animal Weight

175 grams May vary depending on researcher preferences

Maximum Cage Size

42 x 42 x 18 cm May vary depending on research preferences

Battery Life (Months)

Warranted for 4 months

Parameter Measured

Pressure and activity

Outer Material

Silicone Elastomer

Temperature Operating Range

34 to 41 degrees Celsius

Shelf Life

Battery – 1 year, Sterility – 1 year

On-Off Mechanism

Magnetically Actuated

Receiver Compatibility

Any PhysioTel® RLA, RPC-1 or RMC-1
Learn more about DSI Receivers

Measurement Specifications

Pressure Range

-20 to 300 mmHg

Ambient Pressure Range

670 to 800 mmHg

Maximum Altitude

625 meters

Pressure Accuracy

Initial Accuracy

±3 mmHg

Pressure Drift

First month - < 5 mmHg
Second month - < 4 mmHg
Thereafter - < 3 mmHg per month

Specifications are nominal. Some parameters, such as minimum animal weight, may vary depending on research methodology and preference. For example, some researchers have implanted the DSI PhysioTel® PA-C40 transmitter in rats smaller than 175 grams. Minimum animal weight may vary based upon placement location, surgical skill and strain of animal used. Larger cage sizes also can be accommodated with special configurations. Specifications, performance and accuracy are valid for the warranted battery life and only when data are recorded using Dataquest A.R.T. with factory-supplied calibration values. Transmitters may work over wider ranges with reduced accuracy.

When measuring pressure in mice, small animals, and large animals using DSI transmitters, it may be necessary to use an Ambient Pressure Reference Monitor to ensure accurate pressure measurements.

PhysioTel® Transmitter Specifications

Request more information on this product.

PhysioTel® PA-C40 Small Animal Transmitter
PhysioTel® PA-C40 Small Animal Transmitter