Remarkably Sensitive Device Enables New Research Possibilities |
DSI now offers a dual pressure transmitter for the precise measurement of various physiologic signal combinations such as:
- Left ventricular pressure + blood pressure (BP)
- Pulmonary artery pressure + BP
- Right ventricular pressure + BP
- Pleural pressure + BP
- Bladder pressure + BP, and more!
Scientists seeking greater parameter accuracy (e.g. dP/dt) will find the HD-S21 to be ideal for high-fidelity applications.
|
|
![]() |
Other Important HD-S21 Benefits:
- New catheter design offers precise detection of key pressure signal attributes
- Excellent pressure channel stability
- In addition to pressure, collect a biopotential,
- temperature and activity data!
Eliminate variability associated with collecting a single pressure from two separate animal groups (chronically or acutely), all from conscious, freely-moving animals.
![]() |
| Left ventricular pressure, arterial blood pressure and electrocardiogram data example shown. Temperature and activity are also simultaneously collected. |
Digital Data Simplifies Study Management

- auto-loading of calibration data reduces configuration time and eliminates data entry error
- animal ID ensures data collection is from the intended animal
- battery ON-time counter helps track study duration and remaining battery life
Built to Last
The HD-S21 features a hermetic electronics packaging design to prevent moisture ingress among device components.
| HD-S21 Specifications | |
| Appropriate Animal Models | Rats, ferrets, marmosets, guinea pigs and more. |
| Weight | 8 grams |
| Volume | 5.9 cc |
| Minimum Animal Weight | 175 grams |
| Maximum Cage Size* | 42 X 42 X 18 cm |
| Battery Life | Warranted For 2 Months |
| Implant Duration | Warranted For 9 Months |
| Parameters Measured | Two pressures, biopotential, temperature, activity, battery ON time and battery voltage |
| Temperature Operating Range | 34 To 41 degrees Celsius |
| On-Off Mechanism | Activated by holding a magnet near the device for 2 seconds while confirming with presence of tone with radio tuned to low end of AM band. |
| Software Compatibility | Dataquest A.R.T. 4.3, OpenART 4.3, Ponemah 5.0 |
| Hardware Compatibility | Compatible with existing DSI Physiotel* Hardware |
| Pressure Channel Specifications | |
| Pressure Range | -20 To 300 mmHg |
| Catheter Length Options | 8, 10 or 15cm |
| Ambient Pressure Range | 670 To 800 mmHg |
| Initial Accuracy | ± 3 mmHg |
| Pressure Channel Drift | <2mmHg/month (Maximum); -0.25mmHg/month (Average) |
| Frequency Response | 8cm catheter†: >100Hz (Minimum Performance), 120Hz (Average Performance) |
| Biopotential Channel Specifications | |
| Biopotential Input Range | ±5mV |
| Biopotential Input Bandwidth | 0.1-145 Hz |
| Biopotential Lead Length | 30 cm or 60 cm |
| Digital Data Information | |
| Battery ON Time | Track study duration and device use; accurate within ± 1.5 days at body temperature (i.e. -37°C) |
| Animal ID (serial Number) | Transmission of ID to assigned receiver prevents wrong data collection |
| Calibrations | Simplifies configuration and ensures accurate calibration entry |
*Multiple receivers can be used to provide coverage for cages of larger dimensions.